As intelligent moxibustion robots gain popularity in nursing homes, rehabilitation centers, and households, proper daily maintenance and cleaning have become critical for ensuring therapeutic efficacy and extending device lifespan. This guide provides scientifically validated protocols to help users avoid operational errors.
Core Maintenance: Precision Care for Three Key Modules
1. Moxa Head Unit
Residue Removal: After each use, clean ash deposits with an anti-static soft brush. Wipe the surface with 75% medical alcohol pads to prevent oxidation.
Temperature Calibration: Monthly calibration of temperature sensors (error margin < ±1.5°C). Contact manufacturers if heating exceeds standard rates (e.g., >2 minutes to reach 50°C).
2. Robotic Arm Joints
Lubrication: Apply FDA-approved food-grade silicone lubricant to 6-axis bearings quarterly to prevent deviations in "rotary moxibustion" or "sparrow-pecking" motions.
Debris Prevention: Inspect rail gaps post-use. Remove moxa fiber residues using compressed air blowers.
3. Air Filtration System
Filter Replacement: Replace HEPA filters every 3 months (PM2.5 filtration efficiency ≥99.97%) and activated carbon layers biannually.
Duct Sanitization: Weekly 10-minute UV-C light disinfection (265nm wavelength) in airflow channels to inhibit bacterial growth.
Deep Cleaning Protocols: Scenario-Based Procedures
Home Users: Weekly "3-Step Cleaning"
Power Off & Cool Down: Wait 30 minutes after shutdown until temperature drops below 35°C.
Modular Disassembly: Detach moxa chamber, filter tray, and base per manual instructions (secure magnetic connectors).
Eco-Friendly Cleaning: Mix baking soda and citric acid (2:1 ratio) to wipe surfaces, avoiding corrosive chemicals that damage nano-coatings.
Institutions: Professional Sterilization
Ozone Sterilization: Activate built-in ozone generators nightly (0.1ppm concentration for 20 minutes).
Biofilm Prevention: Use enzyme-based cleaners with catalase for monthly pipeline deep-cleaning.
Critical Prohibitions: High-Risk Operations to Avoid
❌ Never rinse the main unit with water (IPX4 rating only protects against splashes).
❌ Avoid abrasive tools on touchscreens (AG glass surfaces scratch easily, causing touch failure).
❌ Never mix moxa sticks from different brands (combustion temperature variations may damage thermal controls).
AI Self-Diagnostics: Smart Troubleshooting
Next-gen robots feature autonomous diagnostics:
Press [Power + Mode] for 5 seconds to activate "Deep Scan Mode".
Interpret error codes (e.g., E02=filter blockage; E15=joint torque anomaly).
Sync with manufacturer’s app via Bluetooth to generate maintenance reports and schedule technician visits.
Data-Driven Benefits of Proper Maintenance
Studies show regular upkeep reduces failure rates by 67% and improves temperature stability by 42% (2023 Intelligent Physiotherapy Device Whitepaper). This guide helps users maintain precision in "hovering moxibustion" and "reciprocating" techniques while minimizing hygiene-related cross-contamination risks.